Kategorije

Impresum

PROBUS K.I.G d.o.o.
Kutinska 15, N.S.P.
HR-44202 Sisak
CROATIA
tel. +385 44743190
fax. +385 44743191
email: Ova e-mail adresa je zaštićena od spam botova. Vaš JavaScript treba biti uključen da bi ju vidjeli.



Fotometar za akvakulturu - HI83303

Osnovna cijena za varijantu 4.568,05 kn
5.710,08 kn
Cijena bez PDV-a: 4.568,05 kn
Iznos PDV-a 1.142,03 kn
HI83303-01
Opis

HI83303 is a compact, multiparameter photometer for use in aquaculture applications. The meter is one of the most advanced photometers available with an innovative optical design that utilizes a reference detector and focusing lens to eliminate errors from changes in the light source and from imperfections in the glass cuvette. This meter has 20 different programmed methods measuring 12 key water quality parameters and also offers an absorbance measurement mode for performance verification and for users that would like to develop their own concentration versus absorbance curves. Aquaculture parameters include alkalinity, calcium, nitrite, and phosphate which are critical to maintaining a healthy system. It also contains parameters specific to either a marine or freshwater environment.

To save valuable laboratory benchtop space, the HI83303 doubles as a professional pH meter with its digital pH/temperature electrode input. Now one meter can be used for both photometric and pH measurements.

 

 

pH

pH Range Photometer: 6.5 to 8.5 pH
pH electrode: -2.00 to 16.00 pH
pH Resolution Photometer: 0.1 pH
pH electrode: 0.01 pH
pH Accuracy Photometer: ±0.1 pH
pH electrode: ±0.01 pH
pH Calibration Automatic one or two point calibration with one set of standard buffers available (4.01, 6.86, 7.01, 9.18, 10.01)
pH Temperature Compensation Automatic (-5.0 to 100.0 oC; 23.0 to 212.0 oF); limits reduced based on the pH electrode used
pH CAL Check (electrode diagnostics) clean electrode and check buffer/check probe displayed during calibration
pH Method Photometer: phenol red
pH-mV Range ±1000 mV
pH-mV Resolution 0.1 mV
pH-mV Accuracy ±0.2 mV

Oxygen, Dissolved

Oxygen, Dissolved Range 0.0 to 10.0 mg/L (as O2)
Oxygen, Dissolved Resolution 0.1 mg/L
Oxygen, Dissolved Accuracy ±0.4 mg/L ±3% of reading
Oxygen, Dissolved Method Adaptation of the Standard Methods for the Examination of Water and Wastewater, 18th edition, Azide modified Winkler method

Absorbance

Absorbance Range 0.000 to 4.000 Abs
Absorbance Resolution 0.001 Abs
Absorbance Accuracy +/-0.003Abs @ 1.000 Abs

Alkalinity

Alkalinity Range Freshwater: 0 to 500 mg/L (as CaCO3)
Seawater: 0 to 300 mg/L (as CaCO3)
Alkalinity Resolution 1 mg/L
Alkalinity Accuracy ±5 mg/L ±5% of reading
Alkalinity Method Colorimetric method

Ammonia

Ammonia Range Low Range: 0.00 to 3.00 mg/L
Medium Range: 0.00 to 10.00 mg/L
High Range: 0.0 to 100.0 mg/L
(all as NH3-N)
Ammonia Resolution Low and Medium Range: 0.01 mg/L
High Range: 0.1 mg/L
Ammonia Accuracy Low Range: ±0.04 mg/L ±4% of reading
Medium Range: ±0.05 mg/L ±5% of reading
High range: ±0.5 mg/L ±5% of reading
Ammonia Method Adaptation of the ASTM Manual of Water and Environmental Technology, D1426-92, Nessler method

Calcium

Calcium Range Freshwater: 0 to 400 mg/L (as Ca2+)
Seawater: 200 to 600 mg/L (as Ca2+)
Calcium Resolution 1 mg/L
Calcium Accuracy Freshwater: ±10 mg/L ±5% of reading
Seawater: ±6% of reading
Calcium Method Freshwater: Adaptation of the Oxalate method
Seawater: Adaptation of the Zincon method

Chlorine

Free Chlorine Range 0.00 to 5.00 mg/L (as Cl2)
Free Chlorine Resolution 0.01 mg/L
Free Chlorine Accuracy ±0.03 mg/L ±3% of reading
Total Chlorine Range 0.00 to 5.00 mg/L (as Cl2)
Total Chlorine Resolution 0.01 mg/L
Total Chlorine Accuracy ±0.03 mg/L ±3% of reading
Chlorine Method Adaptation of the EPA 330.5 DPD method

Copper

Copper Range Low Range: 0.000 to 1.500 mg/L (as Cu2+)
High range: 0.00 to 5.00 mg/L (as Cu2+)
Copper Resolution 0.001 mg/L; 0.01 mg/L
Copper Accuracy Low Range: ±0.01 mg/L ±5% of reading
High Range ±0.02 mg/L ±4% of reading
Copper Method Adaptation of the EPA bicinchoninate method

Nitrate

Nitrate Range 0.0 to 30.0 mg/L (as NO3-- N)
Nitrate Resolution 0.1 mg/L
Nitrate Accuracy ±0.5 mg/L ±10% of reading
Nitrate Method Adaptation of the cadmium reduction method

Nitrite

Nitrite Range Freshwater
Low Range: 0 to 600 μg/L (as NO2--N)
High Range: 0 to 150 mg/L (as NO2-)
Seawater Ultra Low Range: 0 to 200 μg/L (as NO2--N)
Nitrite Resolution Freshwater: 1 μg/L; 1 mg/L
Seawater: 1 μg/L
Nitrite Accuracy Freshwater
Low Range: ±20 μg/L ±4% of reading
High Range: ±4 mg/L ±4% of reading
Seawater
±10 μg/L ±4% of reading
Nitrite Method Low Range and Seawater: Adaptation of the EPA Diazotization method 354.1
High Range: Adaptation of the Ferrous Sulfate method

Phosphate

Phosphate Range Freshwater
Low Range: 0.00 to 2.50 mg/L (as PO43-)
High range: 0.0 to 30.0 mg/L(as PO43-)
Seawater Ultra Low Range: 0 to 200 μg/L (as P)
Phosphate Resolution Freshwater: 0.01 mg/L; 0.1 mg/L
Seawater: 1 μg/L
Phosphate Accuracy Freshwater
Low Range: ±0.04 mg/L ±4% of reading
High Range: ±1 mg/L ±4% of reading
Seawater Ultra Low Range: ±5 μg/L ±5% of reading
Phosphate Method Freshwater Low Range: Adaptation of the Ascorbic Acid method
Freshwater High Range and Seawater Ultra Low Range: Adaptation of the Standard Methods for the Examination of Water and Wastewater, 18th edition, Amino Acid method

General Meter

Input Channels 1 pH electrode input and 5 photometer wavelengths
pH Electrode digital pH electrode (not included)
Logging Type log on demand with user name and sample ID optional input
Logging Memory 1000 readings
Connectivity USB-A host for flash drive; micro-USB-B for power and computer connectivity
GLP calibration data for connected pH electrode
Display 128 x 64 pixel LCD with backlight
Battery Type / Life 3.7 VDC Li-polymer rechargeable battery / >500 photometric measurements or 50 hours of continuous pH measurement
Power Supply 5 VDC USB 2.0 power adapter with USB-A to micro-USB-B cable (included)
Environment 0 to 50.0 oC (32 to 122.0 oF); 0 to 95% RH, non-condensing
Dimensions 206 x 177 x 97 mm (8.1 x 7.0 x 3.8")
Weight 1.0 kg (2.2 lbs.)
Photometer/Colorimeter Light Source 5 LEDs with 420 nm, 466 nm, 525 nm, 575 nm, and 610 nm narrow band interference filters
Photometer/Colorimeter Light Detector silicon photodetector
Bandpass Filter Bandwidth 8 nm
Bandpass Filter Wavelength Accuracy ±1 nm
Cuvette Type round, 24.6 mm
Number of Methods 128 max.
Ordering Information HI83303 is supplied with sample cuvettes and caps (4 ea.), cloth for wiping cuvettes, USB to micro USB cable connector, power adapter and instruction manual.

Ostali proizvodi iz Ponude PROBUS Grupe

Naša ponuda sadrži veliki broj instrumenata iz područja mjerne tehnike za mobilno i fiksno mjerenje i analizu različitih fizikalnih, kemijskih ili električnih veličina. Mjerni uređaji su robusni i visoke kvalitete. ISO 9000 kalibracijske certifikate isporučujemo za gotovo sve mjerne uređaje. U popisu koji slijedi možete pregledavati različite mjerne uređaje tj. grupe proizvoda poredane unutar specifičnih kategorija po abecednom redoslijedu. Tehničke podatke za svaki proizvod, cijenu i ostale informacije možete dobiti klikom na određeni proizvod.

Ako ste pronašli željeni proizvod možete nastaviti kupnju u našoj internet trgovini. Ukoliko niste pronašli odgovarajući uređaj za Vaše potrebe nazovite nas na tel. +385 44743190 ili pošaljite upit na e-mail Ova e-mail adresa je zaštićena od spam botova. Vaš JavaScript treba biti uključen da bi ju vidjeli. i rado ćemo Vam pomoći u odabiru potrebnog proizvoda.

Termometri za HACCP

 

Termometri

HACCP prospekt <<< klikni

Hanna Checker!

prvi low cost digitalni testeri za vodu

Checker
www.prochecker.hr

Data Loggeri za temperaturu

Microlite - povoljan data logger za temperaturu


PROSPEKT <<< klikni

TFA katalog 2013

Ove web stranice koriste kolačiće radi što boljeg iskustva posjetitelja stranice. Molimo da prije korištenja web stranice pročitate opće uvjete korištenja, uvjete zaštite osobnih podataka i Informacije o kolačićima. Klikom na poveznicu 'Zatvori' potvrđujete prihvaćanje kolačića na ovim stranicama.